Next Post in 56 seconds
BASECODE
Server Time : 04-26-2024 04:57:16
Last Post : 04-26-2024 04:57:07
LastLine File: 04-26-2024 04:56:07
PSANDLER - 01000507 | RENEWFEE : 0 (02-09-2044)
===============================================================
IP Address: 45.50.90.181
LOCATION : Cypress, CA (TZ: America/Los_Angeles)
SEC NL/LL: 17819 | 17759
SEC/MIN DIFF : 60 | 1
HOUR : 4
DEBUG : 0
TYPE : GEM | CODE : GEM
Panels : 44
Inverter 1 | 24 panels
Inverter 2 | 20 panels
Main : 1
Net Meter : 11595482
Total Gen : 0
Nightly Reset : Completed
RESP: GOT OK
=============PROCESSED VALUES==================================
CH | Name | Mul | Hide | Neg | New Line | Last Line | Diff | Total | MAX | Trig/Stat | Alert | Time Online | Usage |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
s5 | Main | - | 11,595,482 | 11,559,153 | 36,329 | 3.221 kw | 250,029,079 | ||||||
c2 | Pool Sub | 1 | 1 | 529,579 | 527,784 | 1,795 | 0.15 kw | 200,001,756 | |||||
c3 | Inverter 1 | 2 | 1 | 0 | 0 | 0 | 0 kw | 400,000,000 | 3000 off | 172654 | |||
c4 | Inverter 2 | 2 | 1 | 0 | 0 | 0 | 0 kw | 400,000,000 | 3000 off | 147546 | |||
c5 | HVAC | 1 | 1,502,748 | 1,502,335 | 413 | 0.42 kw | 200,000,365 | ||||||
c6 | Lights | 1 | 1,340,496 | 1,336,121 | 4,375 | 0.37 kw | 200,006,830 | ||||||
c7 | Outlets | 1 | 4,280,391 | 4,263,851 | 16,540 | 1.19 kw | 200,005,841 | ||||||
c8 | Pool Light | 1 | 0 | 0 | 0 | 0 | 0 kw | 200,000,000 | |||||
c9 | Steam Bath | 2 | 0 | 208,036 | 207,230 | 806 | 0.06 kw | 200,000,800 | |||||
c10 | Test Bench | 1 | 107,593 | 107,193 | 400 | 0.03 kw | 200,000,302 | ||||||
c11 | Stove | 2 | 129,036 | 128,590 | 446 | 0.04 kw | 200,000,438 | ||||||
c12 | Dryer | 2 | 3,962 | 3,956 | 6 | 0 kw | 200,000,018 | ||||||
c13 | Attic Fan | 1 | 0 | 0 | 0 | 0 kw | 200,000,000 | ||||||
c14 | A Side | 1 | 1 | 1 | 2,460,591 | 2,457,166 | 3,425 | 0.68 kw | 200,003,448 | ||||
c15 | B Side | 1 | 1 | 1 | 9,134,891 | 9,101,987 | 32,904 | 2.54 kw | 200,025,631 | ||||
c16 | Pool Light | 1 | 0 | 0 | 0 | 0 kw | 200,000,000 | ||||||
c33 | Unmonitored | 1 | 1 | 3,813,841 | 3,801,381 | 12,460 | 1.06 kw | 200,014,399 | |||||
c46 | Over Usage | 1 | 0 | 11,566,403 | 11,530,074 | 36,329 | 3.21 kw | 500,000,000 | |||||
c48 | PT Volts | 1 | 1 | 1 | 240 | 240 | -1 | 239.8 v | 200,000,239 |
==== TEMP SENSORS : Incoming=C | Display=F ====
T1 : Enclosure (65.3)
============ RELAYS =======================
Relay 1: false,false,false,false (10-13-2023 16:23:06)
1:Attic Fan:false
2:Pool Light:false
3:Web Cam1:false
4:Spa Light:false
=========== INCOMING VALUES ===============
GET : 04-26-2024 04:57:07
SN = 01000507
SC = 17819
V = 1199
c1 = 1681,0,0.18
c2 = 529579,0,0.48
c3 = 86327,0,0.36
c4 = 73773,0,0.28
c5 = 1502748,0,2.14
c6 = 1340496,0,2.48
c7 = 4280391,0,2.58
c8 = 0,0,0
c9 = 104018,0,2.16
c10 = 107593,0,2.30
c11 = 64518,0,0.16
c12 = 1981,0,0.22
c13 = 0,0,0
c14 = 2460591,0,1.04
c15 = 9134891,0,5.30
c16 = 0,0,0
c17 = 0,0,0
c18 = 0,0,0
c19 = 0,0,0
c20 = 0,0,0
c21 = 0,0,0
c22 = 0,0,0
c23 = 159420,0,14.44
c24 = 0,0,0
c25 = 0,0,0
c26 = 0,0,0
c27 = 0,0,0
c28 = 0,0,0
c29 = 0,0,0
c30 = 0,0,0
c31 = 0,0,0
c32 = 668,0,0.08
PL = 0,0,0,0
T = 65.3,0,0,0,0,0,0,0
key =
Resp = OK
AMPS :
c1 = 0.18
c2 = 0.48
c3 = 0.72
c4 = 0.56
c5 = 2.14
c6 = 2.48
c7 = 2.58
c8 = 0
c9 = 4.32
c10 = 2.3
c11 = 0.32
c12 = 0.44
c13 = 0
c14 = 1.04
c15 = 5.3
c16 = 0
c17 = 0
c18 = 0
c19 = 0
c20 = 0
c21 = 0
c22 = 0
c23 = 0
c24 = 0
c25 = 0
c26 = 0
c27 = 0
c28 = 0
c29 = 0
c30 = 0
c31 = 0
c32 = 0
=======================
LAST RAW POST FILE
04-26-2024 04:57:07
SN=01000507
SC=17819
V=1199
c1=1681,0,0.18
c2=529579,0,0.48
c3=86327,0,0.36
c4=73773,0,0.28
c5=1502748,0,2.14
c6=1340496,0,2.48
c7=4280391,0,2.58
c8=0,0,0
c9=104018,0,2.16
c10=107593,0,2.30
c11=64518,0,0.16
c12=1981,0,0.22
c13=0,0,0
c14=2460591,0,1.04
c15=9134891,0,5.30
c16=0,0,0
c17=0,0,0
c18=0,0,0
c19=0,0,0
c20=0,0,0
c21=0,0,0
c22=0,0,0
c23=159420,0,14.44
c24=0,0,0
c25=0,0,0
c26=0,0,0
c27=0,0,0
c28=0,0,0
c29=0,0,0
c30=0,0,0
c31=0,0,0
c32=668,0,0.08
PL=0,0,0,0
T=18.5,,,,,,,
key=
Resp=OK
CODE TRACE:
-------------------
Starting ll code
Writting LastRawPost file
Packet Check GEM
Packet Check - Passed
Loading MainConfig
Loading Default Conversion Layer
Custom Conversion Layer NOT LIVE YET
Inverter Generation Check:
c3 : 406 NL - 0 LL = 406 / 1 = 406
c4 : 506 NL - 0 LL = 506 / 1 = 506
MainConfig Load Complete
Entering DebugCode
DebugCode Complete
Good Serial
Got Last1Line
End ll code